5V
Home    |    Products    |    INTERFACE    |    RS485    |    5V

GI485EENL

Production information
ESD-Enhanced, Fail-safe, Slew-Rate-limited
RS-485/RS-422 Transceivers
Request full datasheet:  Click here 
The GI485 +5V, half-duplex, ±16kV ESDprotected RS-485/RS-422-compatible transceivers feature one driver and one receiver.

The GI485 include a hot-swap capability to eliminate false transitions on the bus during power-up or live insertion.

The GI485 features reduced slew-rate drivers that minimize EMI and reduce reflections caused by improperly terminated cables, allowing error-free transmission up to 1Mbps.

The GI485 feature a 1/8-unit load receiver input impedance, allowing up to 256 transceivers on the bus. These devices are intended for half-duplex communications. All driver outputs are protected to ±16kV ESD using the Human Body Model and ±16kV ESD using the Air-Gap Discharge Model.

TheGI485 is available in an 8-pin SO package.

The devices operate over the extended -40°C to +125°C temperature range.
Supply Voltage VCC...............................................................+6V
DE, RE-, DI..................................................................................-0.3V to +6
A, B...............................................................................................-8V to +13V
Short-Circuit Duration (RO, A, B) to GND .....................Continuous
Continuous Power Dissipation (TA = +70°C)
8-Pin SO (derate 5.9mW/°C above +70°C)....................471mW
Operating Temperature Range .........................................-40°C to +125°C
Junction Temperature...........................................................+150°C
Storage Temperature Range .............................................-65°C to +150°C
Lead Temperature (soldering 10s) ..................................+300°C

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
  • +5V Operation
  • Hot-Swappable for Telecom Applications
  • Enhanced Slew-Rate Limiting Facilitates Error-Free Data Transmission
  • Extended ESD Protection for RS-485 I/O Pins ±16kV
  • High fanout driving 1/8Unit load , Allowing up to 256 Transceivers on the Bus.
  • 8 Pin-SO Package
  • Isolated RS-485 Interfaces
  • Utility Meters
  • Industrial Controls
  • Industrial Motor Drives
  • Automated HVAC Systems